18.1.6 When the symbol shown in Figure 18.1 is used in accordance with 18.1.5(c), the installation
instructions provided with the product shall include a definition of the symbol.
Exception: When the symbol in Figure 18.1 is used with one of the other means of identification specified
in 18.1.5 (a) and (b), the definition is not required to be provided.
18.1.6 added March 29, 1999
This is generated text for figtxt.
18.2 Bonding
18.2.1 A noncurrent-carrying metal part shall be bonded to the point of connection of the grounding
conductor. For a pump equipped with a box for supply connections that is remote from the motor or pump,
a green colored lead in the interconnecting cable, terminated as described in 18.1.2, may be used for
bonding. A submersible deep-well or shallow-well pump may be provided with a green-identified deep-well
cable conductor the same size as the circuit conductors or with terminals on both the outside of the pump
housing and the inside or outside of the supply connection box (when provided). The grounding terminal
shall comply with the requirements in 18.1.4.
18.2.2 Solder alone shall not be used to secure grounding and bonding connections. Means for
accomplishing bonding and grounding shall penetrate all nonconductive coatings such as paint.
18.2.3 A bolted or screwed connection that incorporates a star washer under a screw head, a serrated
screw head, or the equivalent is acceptable for penetrating nonconductive coatings as required by 18.2.2.
Figure 18.1
Grounding symbol
Figure 18.1 added March 29, 1999
SEPTEMBER 28, 2000MOTOR-OPERATED WATER PUMPS - UL 77830